Home  /  Tools Apps  / HydroWiz Pipe Flow Hydraulics on Windows Pc

HydroWiz Pipe Flow Hydraulics on Windows Pc

Developed By: Tony Renzullo

License: Free

Rating: 3,7/5 - 92 votes

Last Updated: April 18, 2024

Download on Windows PC

Compatible with Windows 10/11 PC & Laptop

App Details

Version 3.3
Size 4.1 MB
Release Date December 10, 23
Category Tools Apps

What's New:
Bug fix [see more]

Description from Developer:
HydroWiz was designed to be a versatile tool to help engineers find solutions to common pipe flow hydraulics problems allowing them to perform quick "what if?" calculatio... [read more]

App preview ([see all 9 screenshots])

App preview

About this app

On this page you can download HydroWiz Pipe Flow Hydraulics and install on Windows PC. HydroWiz Pipe Flow Hydraulics is free Tools app, developed by Tony Renzullo. Latest version of HydroWiz Pipe Flow Hydraulics is 3.3, was released on 2023-12-10 (updated on 2024-04-18). Estimated number of the downloads is more than 10,000. Overall rating of HydroWiz Pipe Flow Hydraulics is 3,7. Generally most of the top apps on Android Store have rating of 4+. This app had been rated by 92 users, 15 users had rated it 5*, 46 users had rated it 1*.

How to install HydroWiz Pipe Flow Hydraulics on Windows?

Instruction on how to install HydroWiz Pipe Flow Hydraulics on Windows 10 Windows 11 PC & Laptop

In this post, I am going to show you how to install HydroWiz Pipe Flow Hydraulics on Windows PC by using Android App Player such as BlueStacks, LDPlayer, Nox, KOPlayer, ...

Before you start, you will need to download the APK/XAPK installer file, you can find download button on top of this page. Save it to easy-to-find location.

[Note] You can also download older versions of this app on bottom of this page.

Below you will find a detailed step-by-step guide, but I want to give you a fast overview of how it works. All you need is an emulator that will emulate an Android device on your Windows PC and then you can install applications and use it - you see you're playing it on Android, but this runs not on a smartphone or tablet, it runs on a PC.

If this doesn't work on your PC, or you cannot install, comment here and we will help you!

Step By Step Guide To Install HydroWiz Pipe Flow Hydraulics using BlueStacks

  1. Download and Install BlueStacks at: https://www.bluestacks.com. The installation procedure is quite simple. After successful installation, open the Bluestacks emulator. It may take some time to load the Bluestacks app initially. Once it is opened, you should be able to see the Home screen of Bluestacks.
  2. Open the APK/XAPK file: Double-click the APK/XAPK file to launch BlueStacks and install the application. If your APK/XAPK file doesn't automatically open BlueStacks, right-click on it and select Open with... Browse to the BlueStacks. You can also drag-and-drop the APK/XAPK file onto the BlueStacks home screen
  3. Once installed, click "HydroWiz Pipe Flow Hydraulics" icon on the home screen to start using, it'll work like a charm :D

[Note 1] For better performance and compatibility, choose BlueStacks 5 Nougat 64-bit read more

[Note 2] about Bluetooth: At the moment, support for Bluetooth is not available on BlueStacks. Hence, apps that require control of Bluetooth may not work on BlueStacks.

How to install HydroWiz Pipe Flow Hydraulics on Windows PC using NoxPlayer

  1. Download & Install NoxPlayer at: https://www.bignox.com. The installation is easy to carry out.
  2. Drag the APK/XAPK file to the NoxPlayer interface and drop it to install
  3. The installation process will take place quickly. After successful installation, you can find "HydroWiz Pipe Flow Hydraulics" on the home screen of NoxPlayer, just click to open it.

Discussion

(*) is required

HydroWiz was designed to be a versatile tool to help engineers find solutions to common pipe flow hydraulics problems allowing them to perform quick "what if?" calculations easily. It would also be useful to anyone working on simple water transfer projects involving pipes. The app solves the Darcy-Weisbach equation, the Colebrook-White equation and Bernoulli's equation to perform a range of hydraulic calculations on a single length of pipe between two known points.

NOTE - HydroWiz Lite is intended mainly for evaluation purposes. System options 2, 3 and 4 below are not available in this version. Download HydroWiz Pro to have all the features available.

MAIN CALCULATIONS
• ΔP Pressure Loss - calculates the pressure loss between P1 and P2.
• Q Flow Rate - calculates the volumetric flow rate in the pipe.
• D Internal Diameter - calculates the internal diameter of the pipe.
• L Pipe Length - calculates the pipe length for the given conditions.

OTHER CALCULATION RESULTS
• Elevation head.
• Head loss.
• Hydraulic head.
• Friction loss.
• Fittings loss.
• Velocity head.
• Flow velocity.
• Mass flow.
• Flow type.
• Reynolds number.
• Friction factor.

INPUT REQUIREMENTS
• ΔP Pressure Loss - Elevation Change, Flow Rate, Internal Diameter and Pipe Length.
• Q Flow Rate - Elevation Change, Pressure Loss, Internal Diameter and Pipe Length.
• D Internal Diameter - Elevation Change, Pressure Loss, Flow Rate and Pipe Length.
• L Pipe Length - Elevation Change, Pressure Loss, Flow Rate and Internal Diameter.

SYSTEM AND UNIT OPTIONS
1. Preferred units of measurement in both SI/Metric and US/Imperial units.
2. Pipe roughness coefficients from a range of pipe materials.
3. Resistance coefficients from commonly used pipe fittings and valves.
4. Fluid properties from a range of fluids including fresh water and sea water at different temperatures.
NOTE - Options 2, 3 and 4 above are only available in HydroWiz Pro.

NOTE ON CRITICAL FLOW ZONE (2300 < Re < 4000)
It is well recognized that the flow within this narrow zone is unpredictable, unstable and not fully understood. The best practice is to design within the laminar flow or turbulent flow zones to avoid potential problems and uncertainty. Any calculation falling within this zone will be issued with a warning. The calculated results are interpolations and difficult to predict with accuracy due to both friction factor and flow instability.
Bug fix