Home  /  Education Apps  / Transformer Spray design on Windows Pc

Transformer Spray design on Windows Pc

Developed By: FrankEngineer

License: Free

Rating: 5,0/5 - 1 votes

Last Updated: April 18, 2024

Download on Windows PC

Compatible with Windows 10/11 PC & Laptop

App Details

Version 1.0
Size 2.9 MB
Release Date December 19, 15
Category Education Apps

Description from Developer:
The Standard for Water Spray Fixed Systems for Fire Protection, formerly Water Spray Nozzles and
Extinguishing Systems, first prepared by the Committee on Manufacturing Hazards, wa... [read more]

App preview ([see all 25 screenshots]  /  [view video])

App preview

About this app

On this page you can download Transformer Spray design and install on Windows PC. Transformer Spray design is free Education app, developed by FrankEngineer. Latest version of Transformer Spray design is 1.0, was released on 2015-12-19 (updated on 2024-04-18). Estimated number of the downloads is more than 10. Overall rating of Transformer Spray design is 5,0. Generally most of the top apps on Android Store have rating of 4+. This app had been rated by 1 users, 1 users had rated it 5*, 1 users had rated it 1*.

How to install Transformer Spray design on Windows?

Instruction on how to install Transformer Spray design on Windows 10 Windows 11 PC & Laptop

In this post, I am going to show you how to install Transformer Spray design on Windows PC by using Android App Player such as BlueStacks, LDPlayer, Nox, KOPlayer, ...

Before you start, you will need to download the APK/XAPK installer file, you can find download button on top of this page. Save it to easy-to-find location.

[Note] You can also download older versions of this app on bottom of this page.

Below you will find a detailed step-by-step guide, but I want to give you a fast overview of how it works. All you need is an emulator that will emulate an Android device on your Windows PC and then you can install applications and use it - you see you're playing it on Android, but this runs not on a smartphone or tablet, it runs on a PC.

If this doesn't work on your PC, or you cannot install, comment here and we will help you!

Step By Step Guide To Install Transformer Spray design using BlueStacks

  1. Download and Install BlueStacks at: https://www.bluestacks.com. The installation procedure is quite simple. After successful installation, open the Bluestacks emulator. It may take some time to load the Bluestacks app initially. Once it is opened, you should be able to see the Home screen of Bluestacks.
  2. Open the APK/XAPK file: Double-click the APK/XAPK file to launch BlueStacks and install the application. If your APK/XAPK file doesn't automatically open BlueStacks, right-click on it and select Open with... Browse to the BlueStacks. You can also drag-and-drop the APK/XAPK file onto the BlueStacks home screen
  3. Once installed, click "Transformer Spray design" icon on the home screen to start using, it'll work like a charm :D

[Note 1] For better performance and compatibility, choose BlueStacks 5 Nougat 64-bit read more

[Note 2] about Bluetooth: At the moment, support for Bluetooth is not available on BlueStacks. Hence, apps that require control of Bluetooth may not work on BlueStacks.

How to install Transformer Spray design on Windows PC using NoxPlayer

  1. Download & Install NoxPlayer at: https://www.bignox.com. The installation is easy to carry out.
  2. Drag the APK/XAPK file to the NoxPlayer interface and drop it to install
  3. The installation process will take place quickly. After successful installation, you can find "Transformer Spray design" on the home screen of NoxPlayer, just click to open it.

Discussion

(*) is required

Download older versions

Other versions available: 1.0.

Download Transformer Spray design 1.0 on Windows PC – 2.9 MB

The Standard for Water Spray Fixed Systems for Fire Protection, formerly Water Spray Nozzles and
Extinguishing Systems, first prepared by the Committee on Manufacturing Hazards, was tentatively adopted in 1939, with final adoption in 1940. Subsequently, this standard was placed under the jurisdiction of the Committee on Special Extinguishing Systems, and a new edition was adopted in 1947. In 1959, the committee organization was further changed to place primary responsibility in the hands of the Committee on Water Spray, under the general supervision of the General Committee on Special Extinguishing Methods. In 1966, the General Committee on Special Extinguishing Methods was discontinued, and the Committee on
Water Spray was constituted as an independent committee. Revised editions were presented
in 1969, 1973, 1977, 1979, and 1982.
Download Manule Link: https://drive.google.com/file/d/0BxaWWGlfYY6NQUk1SGE1UkwtWnM/view?usp=sharing
1.1.1 This standard provides the minimum requirements for the design, installation, and system acceptance testing of water spray fixed systems for fire protection service and the minimum requirements for the periodic testing and maintenance of ultra-high-speed water spray fixed systems.
1.1.2* Water spray fixed systems shall be specifically designed to provide for effective fire control, extinguishment, prevention, or exposure protection.
1.1.3* This standard shall not apply to water spray protection
from portable nozzles, sprinkler systems, monitor nozzles, water
mist suppression systems, explosion suppression, or other means
of application covered by other standards of NFPA.
1.2 Purpose. The purpose of this standard shall be to provide
the minimum requirements for water spray fixed systems based
on sound engineering principles, test data, and field experience.
1.3 Application.
1.3.1 Water spray is applicable for protection of specific hazards
and equipment and shall be permitted to be installed independently of, or supplementary to, other forms of fire protection
systems or equipment.
1.3.2 Water spray protection is acceptable for the protection
of hazards involving each of the following groups:
(1) Gaseous and liquid flammable materials
(2) Electrical hazards such as transformers, oil switches, motors, cable trays, and cable runs
(3) Ordinary combustibles such as paper, wood, and textiles
(4) Certain hazardous solids such as propellants and pyrotechnics
(5) Vapor mitigation
1.4 Retroactivity. The provisions of this standard reflect a consensus of what is necessary to provide an acceptable degree of
protection from the hazards addressed in this standard at the
time the standard was issued.
1.4.1 Unless otherwise specified, the provisions of this standard shall not apply to facilities, equipment, structures, or installations that existed or were approved for construction or
installation prior to the effective date of the standard. Where
specified, the provisions of this standard shall be retroactive.
1.4.2 The retroactive requirements of this standard shall be permitted to be modified if their application clearly would be impractical in the judgment of the authority having jurisdiction, and only where it is clearly evident that a reasonable degree of safety is provided.
1.5 Equivalency. Nothing in this standard is intended to prevent the use of systems, methods, or devices of equivalent or superior quality, strength, fire resistance, effectiveness, durability, and safety over those prescribed by this standard. Technical documentation shall be submitted to the authority having jurisdiction to demonstrate equivalency. The system, method, or device shall be approved for the intended purpose by the authority having jurisdiction.
Function
1. Method Design
2. Number Sprinkler Design
3. Area Calculate
4. Flow Sprinkler Calculate
5. Pressure & Flow Sprinkler Calvulate
6. Frictional Loss Calculate
7. Table For Design
8. Graph For Design