Home  /  Tools Apps  / Relay Code - ANSI - Electrical protections on Windows Pc

Relay Code - ANSI - Electrical protections on Windows Pc

Developed By: Fjapps

License: Free

Rating: 4,5/5 - 15 votes

Last Updated: April 18, 2024

Download on Windows PC

Compatible with Windows 10/11 PC & Laptop

App Details

Version 1.3
Size 5.8 MB
Release Date April 20, 19
Category Tools Apps

App Permissions:
Allows applications to open network sockets. [see more (3)]

What's New:
Relay Code - ANSI - Electrical protections [see more]

Description from Developer:
This app shows the relay codes used in electrical protections according to the ANSI standard.

It allows you to add the most consulted relay codes to favorites and share them by ma... [read more]

App preview ([see all 8 screenshots]  /  [view video])

App preview

About this app

On this page you can download Relay Code - ANSI - Electrical protections and install on Windows PC. Relay Code - ANSI - Electrical protections is free Tools app, developed by Fjapps. Latest version of Relay Code - ANSI - Electrical protections is 1.3, was released on 2019-04-20 (updated on 2024-04-18). Estimated number of the downloads is more than 1,000. Overall rating of Relay Code - ANSI - Electrical protections is 4,5. Generally most of the top apps on Android Store have rating of 4+. This app had been rated by 15 users, 1 users had rated it 5*, 11 users had rated it 1*.

How to install Relay Code - ANSI - Electrical protections on Windows?

Instruction on how to install Relay Code - ANSI - Electrical protections on Windows 10 Windows 11 PC & Laptop

In this post, I am going to show you how to install Relay Code - ANSI - Electrical protections on Windows PC by using Android App Player such as BlueStacks, LDPlayer, Nox, KOPlayer, ...

Before you start, you will need to download the APK/XAPK installer file, you can find download button on top of this page. Save it to easy-to-find location.

[Note] You can also download older versions of this app on bottom of this page.

Below you will find a detailed step-by-step guide, but I want to give you a fast overview of how it works. All you need is an emulator that will emulate an Android device on your Windows PC and then you can install applications and use it - you see you're playing it on Android, but this runs not on a smartphone or tablet, it runs on a PC.

If this doesn't work on your PC, or you cannot install, comment here and we will help you!

Step By Step Guide To Install Relay Code - ANSI - Electrical protections using BlueStacks

  1. Download and Install BlueStacks at: https://www.bluestacks.com. The installation procedure is quite simple. After successful installation, open the Bluestacks emulator. It may take some time to load the Bluestacks app initially. Once it is opened, you should be able to see the Home screen of Bluestacks.
  2. Open the APK/XAPK file: Double-click the APK/XAPK file to launch BlueStacks and install the application. If your APK/XAPK file doesn't automatically open BlueStacks, right-click on it and select Open with... Browse to the BlueStacks. You can also drag-and-drop the APK/XAPK file onto the BlueStacks home screen
  3. Once installed, click "Relay Code - ANSI - Electrical protections" icon on the home screen to start using, it'll work like a charm :D

[Note 1] For better performance and compatibility, choose BlueStacks 5 Nougat 64-bit read more

[Note 2] about Bluetooth: At the moment, support for Bluetooth is not available on BlueStacks. Hence, apps that require control of Bluetooth may not work on BlueStacks.

How to install Relay Code - ANSI - Electrical protections on Windows PC using NoxPlayer

  1. Download & Install NoxPlayer at: https://www.bignox.com. The installation is easy to carry out.
  2. Drag the APK/XAPK file to the NoxPlayer interface and drop it to install
  3. The installation process will take place quickly. After successful installation, you can find "Relay Code - ANSI - Electrical protections" on the home screen of NoxPlayer, just click to open it.

Discussion

(*) is required

Download older versions

Other versions available: 1.3.

Download Relay Code - ANSI - Electrical protections 1.3 on Windows PC – 5.8 MB

This app shows the relay codes used in electrical protections according to the ANSI standard.

It allows you to add the most consulted relay codes to favorites and share them by mail, WhatsApp, among others. Becoming
So in a great tool to read electric plans and electrical protections according to the ANSI standard from your mobile device.

1.- Main Relay Code:

32 - Directional power relay
32L - Low advance power
32N - Wattmetric Zero-Sequence Directional
32P - Directional power
32R - Reverse power
33 - Position switch
34 - Master sequence device
35 - Short circuit device that operates with brushes or sliding ring
36 - Polarization voltage or polarization device
49 - Machine Thermal Relay or Transformer / Thermal Overload
49RTD - RTD polarized thermal overload
50 - Instantaneous overcurrent relay
50BF - Breaker failure
50DD - Current disturbance detector
50EF - End Fault Protection
50G - Instantaneous ground overcurrent
50IG - Instantaneous overcurrent of isolated ground
50LR - Acceleration time
50N - Neutral instantaneous overcurrent
50 NBF - Neutral instantaneous breaker failure
50P - Instantaneous phase overcurrent
50SG - Instant overcurrent of sensitive earth
50SP - Instantaneous split phase current
50_2 - Instantaneous overcurrent of negative sequence
50/27 - Accidental Energization
50/51 - Instantaneous overcurrent / time delay relay
50Ns / 51Ns - Sensitive ground fault protection
50/74 - Ct Trouble
50/87 - Instantaneous Differential
51 - AC time overcurrent relay
51 - Overload
51G - Ground time overcurrent
51LR - AC inverse time overcurrent protection relay (rotor locked)
51N - Neutral time overcurrent
52a - Position of the AC circuit breaker (contact open when the circuit breaker is open)
52b - Position of the AC circuit breaker (contact closed when the circuit breaker is open)

2.- Acronyms:

AFD - Electric arc detector
CLK - Clock or timing source
CLP - Cold load collection
DDR - Dynamic disturbance recorder
DFR - Digital fault recorder
HMI - Human-machine interface
HST - Historian
LGC - Scheme Logic
MET - Measurement of the substation
PDC - phasor data concentrator
PMU - phasor measurement unit
PQM - Energy quality monitor
RIO - Remote input / output device
RTD - Resistance temperature detector
LRSS - Local / remote selector switch
VTFF - Vt Fuse failure