What's New:
V1.001.6 更正導線絕緣溫90度,周溫40度時期修正係數由0.96改為0.95。V1.001.5 在導線絕緣物溫度採60度, 配線採PEX電纜時,配管選用PVC管時其導線安培值將參照PVC線 [絕緣物溫度60度] 配設之安培值檢討... [see more]

Description from Developer:
(Beta version provides single-phase lamp socket type and main switch 30A pipeline diameter query)

(Because the APP requires more text description,
It is recommended to change [Fon... [read more]

App preview ([see all 9 screenshots]  /  [view video])

App preview

About this app

On this page you can download (Beta)電力負載計算(條件限制下開放免費下載) (FREE) and install on Windows PC. (Beta)電力負載計算(條件限制下開放免費下載) (FREE) is free Tools app, developed by TSENG,YU HSIEN. Latest version of (Beta)電力負載計算(條件限制下開放免費下載) (FREE) is 1.001.6, was released on 2021-01-24 (updated on 2023-12-31). Estimated number of the downloads is more than 100. Overall rating of (Beta)電力負載計算(條件限制下開放免費下載) (FREE) is 5,0. Generally most of the top apps on Android Store have rating of 4+. This app had been rated by 1 users, 1 users had rated it 5*, 1 users had rated it 1*.

How to install (Beta)電力負載計算(條件限制下開放免費下載) (FREE) on Windows?

Instruction on how to install (Beta)電力負載計算(條件限制下開放免費下載) (FREE) on Windows 10 Windows 11 PC & Laptop

In this post, I am going to show you how to install (Beta)電力負載計算(條件限制下開放免費下載) (FREE) on Windows PC by using Android App Player such as BlueStacks, LDPlayer, Nox, KOPlayer, ...

Before you start, you will need to download the APK/XAPK installer file, you can find download button on top of this page. Save it to easy-to-find location.

[Note] You can also download older versions of this app on bottom of this page.

Below you will find a detailed step-by-step guide, but I want to give you a fast overview of how it works. All you need is an emulator that will emulate an Android device on your Windows PC and then you can install applications and use it - you see you're playing it on Android, but this runs not on a smartphone or tablet, it runs on a PC.

If this doesn't work on your PC, or you cannot install, comment here and we will help you!

Step By Step Guide To Install (Beta)電力負載計算(條件限制下開放免費下載) (FREE) using BlueStacks

  1. Download and Install BlueStacks at: https://www.bluestacks.com. The installation procedure is quite simple. After successful installation, open the Bluestacks emulator. It may take some time to load the Bluestacks app initially. Once it is opened, you should be able to see the Home screen of Bluestacks.
  2. Open the APK/XAPK file: Double-click the APK/XAPK file to launch BlueStacks and install the application. If your APK/XAPK file doesn't automatically open BlueStacks, right-click on it and select Open with... Browse to the BlueStacks. You can also drag-and-drop the APK/XAPK file onto the BlueStacks home screen
  3. Once installed, click "(Beta)電力負載計算(條件限制下開放免費下載) (FREE)" icon on the home screen to start using, it'll work like a charm :D

[Note 1] For better performance and compatibility, choose BlueStacks 5 Nougat 64-bit read more

[Note 2] about Bluetooth: At the moment, support for Bluetooth is not available on BlueStacks. Hence, apps that require control of Bluetooth may not work on BlueStacks.

How to install (Beta)電力負載計算(條件限制下開放免費下載) (FREE) on Windows PC using NoxPlayer

  1. Download & Install NoxPlayer at: https://www.bignox.com. The installation is easy to carry out.
  2. Drag the APK/XAPK file to the NoxPlayer interface and drop it to install
  3. The installation process will take place quickly. After successful installation, you can find "(Beta)電力負載計算(條件限制下開放免費下載) (FREE)" on the home screen of NoxPlayer, just click to open it.

Discussion

(*) is required

(Beta version provides single-phase lamp socket type and main switch 30A pipeline diameter query)

(Because the APP requires more text description,
It is recommended to change [Font Size] or [Display Size] to default or reduce in [Settings] to facilitate the display of text on the screen)

If the function meets the requirements, please purchase the official version
https://play.google.com/store/apps/details?id=appinventor.ai_sogonetcom.Tools_power_V1_200310_2
---------------------------------
Official version at
2020/5/31 updated to V1.001.9 version (Beta version has not been updated)
2020/6/04 updated to V1.001.10 version (Beta version has not been updated)
2020/6/06 updated to V1.001.12 version (Beta version has not been updated)
2020/7/26 updated to V1.001.13 version (Beta version has not been updated)
2020/9/24 updated to V1.001.19 version (the Beta version has a corresponding update)
2020/10/12 updated to V1.001.20 version (Beta version has not been updated)
Updated on 2021/01/24 to version V1.001.21 (the Beta version has a corresponding update)
---------------------------------
V1.001.21 Corrected the insulation temperature of the wire to 90 degrees, and the correction coefficient during the period of 40 degrees per week was changed from 0.96 to 0.95
V1.001.20 announced on 2020-02-11 [User Electrical Equipment Installation Rules] updated and revised,
Corresponding corrections to the ampere value of various cables.
V1.001.19 takes 60 degrees at the wire insulation temperature,
When PEX cable is used for wiring, when PVC pipe is used for piping, the ampere value of the wire will refer to the PVC wire
[Insulation temperature 60 degrees] Ampere value review of the configuration;
In addition, when the PEX cable is used for the wiring, the ampere value of the wire will refer to the PEX line when the metal tube is used for the piping
[Insulation temperature 60 degrees] Ampere value review of the configuration.
V1.001.18 increases the calculated capacity of the transformer to 250KVA.
V1.001.17 The thick steel conduit (RSG) produced by most factories does not produce G92 pipe diameter. It is recommended to replace it with G104 pipe diameter.
V1.001.13 Because the mains voltage drop may be composed of multiple branched mains (panel or transformer, etc.), the display of the recommended length of the single-stage 2% voltage drop is cancelled.
V1.001.12 adds the category of transformer equipment, and calculates the diameter of transformer 1&2 secondary side protection switch and distribution line (according to Article 177 of the indoor wiring installation rules).
V1.001.11 adds transformer equipment category, and can calculate transformer primary and secondary side protection switch and distribution pipeline diameter.
V1.001.10 adds transformer equipment category, and can calculate transformer primary side protection switch and distribution pipeline diameter
(According to Article 177 of the House Wiring Installation Rules).
V1.001.9 increase
A. For 110-volt appliances, the motor is 1 horsepower, and the others are limited to 5 kW. 220 volt appliance, electric motor with 3 horsepower,
Others are limited to 30 瓩. But without three-phase power supply or other special reasons (such as window-type air conditioners), 110 volt motors must be discharged
As wide as 2 horsepower, the 220-volt motor has to be relaxed to 5 horsepower.
B. Add a reminder when calculating the 3-phase 380V branch circuit (if it is a complete set of equipment and contains single-phase equipment, the N-phase wire diameter needs to be
Adopted according to 3-phase specifications.
C. The main switch primary side pipeline and secondary side copper inspection selection increase source is the connection line and the voltage device options and added
3-phase 4-wire 110-190V field. The grounding wire is corrected according to the above phase selection.
D. It is recommended to use Y-Δ step-down starter for those who increase the horsepower of 3 phase 220V up to 15HP and 3 phase 380V horsepower up to 50HP.
E. When choosing the household connection line or transformer, add the judgment 3-phase 220V and the capacity of the meter device must be below 99KW.
The capacity of the meter device of the 3-phase 4-wire 380V must be below 499KW.
-----------------------------------

Power load calculate-(Power load calculate)

Provides a complete set of power and ampere calculation APP for all kinds of electrical equipment under different voltage, ambient temperature... etc.; this system will propose the NFB, distribution line diameter that should be used after calculation, and 3 The distance of the maximum installation under the condition of% pressure drop is for users to clearly understand and set the same. In addition, for the main switch NFB, the primary side distribution line diameter and the secondary side copper bus specifications are provided according to its capacity.

This system contains two major categories:
1. Calculation of the branch pipeline in the panel: according to different equipment types, voltage, wire insulation temperature, ambient temperature, and pipeline material...
Calculate suitable NFB and pipeline diameter for installation.

2. Main switch primary side pipeline and secondary side copper inspection selection: according to the capacity of the main switch NFB, provide the primary side distribution pipeline diameter and secondary side
Specification of secondary side copper bar.

Congratulations, you found it!
Mechanical and electrical (hydropower) engineering tools.
Such a tool can satisfy your query and calculate the NFB (number of poles-AT/AF) of various electrical loads and a practical small tool for suitable distribution pipeline diameter.

-4.2MB installed space, is a practical tool, super space saving.

Function application

►This system provides the maximum distance (MAX) that the pipeline of the circuit can be equipped with in the load calculation when the shunt pressure drop is less than 3%, so as to avoid the pressure drop >3% caused by the installation length. And violate the regulations.

►The ambient temperature of the wire configuration will affect the ampere capacity of the wire; therefore, this system specially incorporates this factor into the calculation; please pay special attention to the ambient temperature of the wire configuration during the review; include it in the review, and have obtained the appropriate Wire distribution.

If you have any questions or suggestions, please contact line.token@gmail.com
V1.001.6 更正導線絕緣溫90度,周溫40度時期修正係數由0.96改為0.95。
V1.001.5 在導線絕緣物溫度採60度,
配線採PEX電纜時,配管選用PVC管時其導線安培值將參照PVC線
[絕緣物溫度60度] 配設之安培值檢討;
另配線採PEX電纜時,配管選用金屬管時其導線安培值將參照PEX線
[絕緣物溫度60度] 配設之安培值檢討。
Allows applications to open network sockets.
Allows applications to access information about networks.
Allows applications to access information about Wi-Fi networks.
Allows an application to read from external storage.
Allows an application to write to external storage.