V1.001.21 更正導線絕緣溫90度,周溫40度時期修正係數由0.96改為0.95。V1.001.20 針對2020-02-11 公布 [用戶用電設備裝置規則]更新修訂,相關各類電纜線安培值對應修正。 [see more]

Description from Developer:
Power load calculate-(Power load calculate)
(Remind you:
Because some brands of mobile phones in mainland China often delete and modify the Google source code, which may affect the... [read more]

App preview ([see all 9 screenshots]  /  [view video])

App preview

About this app

On this page you can download 電力負載計算-Power load calculate and install on Windows PC. 電力負載計算-Power load calculate is free Tools app, developed by TSENG,YU HSIEN. Latest version of 電力負載計算-Power load calculate is 1.001.20, was released on 2021-01-24 (updated on 2023-12-31). Estimated number of the downloads is more than 5. Overall rating of 電力負載計算-Power load calculate is 5,0. Generally most of the top apps on Android Store have rating of 4+. This app had been rated by 1 users, 1 users had rated it 5*, 1 users had rated it 1*.

How to install 電力負載計算-Power load calculate on Windows?

Instruction on how to install 電力負載計算-Power load calculate on Windows 10 Windows 11 PC & Laptop

In this post, I am going to show you how to install 電力負載計算-Power load calculate on Windows PC by using Android App Player such as BlueStacks, LDPlayer, Nox, KOPlayer, ...

Before you start, you will need to download the APK/XAPK installer file, you can find download button on top of this page. Save it to easy-to-find location.

[Note] You can also download older versions of this app on bottom of this page.

Below you will find a detailed step-by-step guide, but I want to give you a fast overview of how it works. All you need is an emulator that will emulate an Android device on your Windows PC and then you can install applications and use it - you see you're playing it on Android, but this runs not on a smartphone or tablet, it runs on a PC.

If this doesn't work on your PC, or you cannot install, comment here and we will help you!

Step By Step Guide To Install 電力負載計算-Power load calculate using BlueStacks

  1. Download and Install BlueStacks at: https://www.bluestacks.com. The installation procedure is quite simple. After successful installation, open the Bluestacks emulator. It may take some time to load the Bluestacks app initially. Once it is opened, you should be able to see the Home screen of Bluestacks.
  2. Open the APK/XAPK file: Double-click the APK/XAPK file to launch BlueStacks and install the application. If your APK/XAPK file doesn't automatically open BlueStacks, right-click on it and select Open with... Browse to the BlueStacks. You can also drag-and-drop the APK/XAPK file onto the BlueStacks home screen
  3. Once installed, click "電力負載計算-Power load calculate" icon on the home screen to start using, it'll work like a charm :D

[Note 1] For better performance and compatibility, choose BlueStacks 5 Nougat 64-bit read more

[Note 2] about Bluetooth: At the moment, support for Bluetooth is not available on BlueStacks. Hence, apps that require control of Bluetooth may not work on BlueStacks.

How to install 電力負載計算-Power load calculate on Windows PC using NoxPlayer

  1. Download & Install NoxPlayer at: https://www.bignox.com. The installation is easy to carry out.
  2. Drag the APK/XAPK file to the NoxPlayer interface and drop it to install
  3. The installation process will take place quickly. After successful installation, you can find "電力負載計算-Power load calculate" on the home screen of NoxPlayer, just click to open it.

Discussion

(*) is required

Download older versions

Other versions available: 1.001.20.

Download 電力負載計算-Power load calculate 1.001.20 on Windows PC – 4.2 MB

Power load calculate-(Power load calculate)
(Remind you:
Because some brands of mobile phones in mainland China often delete and modify the Google source code, which may affect the execution of the APP, please install (Beta version) first and then purchase the official version after the test is correct)
https://play.google.com/store/apps/details?id=appinventor.ai_sogonetcom.Tools_power_test_V1_200324_1
(Because the APP requires more text description,
It is recommended to change [Font Size] or [Display Size] to default or reduce in [Settings] to facilitate the display of text on the screen)

Provides a complete set of power and ampere calculation APP for all kinds of electrical equipment under different voltage, ambient temperature... etc.; this system will propose the NFB, distribution line diameter that should be used after calculation, and 3 The distance of the maximum configuration under the condition of% pressure drop is for users to clearly understand and set correspondingly. In addition, for the main switch NFB, the primary side distribution line diameter and the secondary side copper bus specifications are provided according to its capacity.

For the one-line diagram calculation APP, please refer to https://play.google.com/store/apps/details?id=appinventor.ai_sogonetcom.Tools_power_PRO_V2_0708_5_9

YouTube video: https://youtu.be/yX-nXkt05WM
------------
V1.001.21 corrected the insulation temperature of the wire to 90 degrees, and the correction coefficient during the period of 40 degrees per week was changed from 0.96 to 0.95.
V1.001.20 announced on 2020-02-11 [User Electrical Equipment Installation Rules] updated and revised,
Corresponding corrections to the ampere value of various cables.
V1.001.19 takes 60 degrees at the wire insulation temperature,
When PEX cable is used for wiring, when PVC pipe is used for piping, the ampere value of the wire will refer to the PVC wire
[Insulation temperature 60 degrees] Ampere value review of the configuration;
In addition, when the PEX cable is used for the wiring, the ampere value of the wire will refer to the PEX line when the metal tube is used for the piping
[Insulation temperature 60 degrees] Ampere value review of the configuration.
V1.001.18 increases the calculated capacity of the transformer to 250KVA.
V1.001.17 The thick steel conduit (RSG) produced by most factories does not produce G92 pipe diameter. It is recommended to replace it with G104 pipe diameter.
V1.001.13 Because the mains voltage drop may be composed of multiple branch mains (panel or transformer... etc.), the single-stage 2% voltage drop recommendation is cancelled
Display of length.
V1.001.12 adds transformer equipment category, and can calculate transformer primary and secondary side protection switch and distribution pipeline diameter
(According to Article 177 of the House Wiring Installation Rules).
-------------
V1.001.9 adds:
A. For 110-volt appliances, the motor is 1 horsepower, and the others are limited to 5 kW. 220 volt appliance, electric motor with 3 horsepower,
Others are limited to 30 瓩. But without three-phase power supply or other special reasons (such as window-type air conditioners), 110 volt motors must be discharged
As wide as 2 horsepower, the 220-volt motor has to be relaxed to 5 horsepower.
B. Add a reminder when calculating the 3-phase 380V branch circuit (if it is a complete set of equipment and contains single-phase equipment, the N-phase wire diameter needs to be
Adopted according to 3-phase specifications.
C. The main switch primary side pipeline and secondary side copper inspection selection increase source is the connection line and the voltage device options and added
3-phase 4-wire 110-190V field. The grounding wire is corrected according to the above phase selection.
D. It is recommended to use Y-Δ step-down starter for those who increase the horsepower of 3 phase 220V up to 15HP and 3 phase 380V horsepower up to 50HP.
E. When choosing the household connection line or transformer, add the judgment 3-phase 220V and the capacity of the meter device must be below 99KW.
The capacity of the meter device of the 3-phase 4-wire 380V must be below 499KW.
-----------------------------------
V1.001.8 adds:
When the shunt rating of the distribution box is less than 30A, the main overcurrent protector should not exceed 200A.
---------------------------------

This system contains two major categories:
1. Calculation of the branch pipeline in the panel: according to different equipment types, voltage, wire insulation temperature, ambient temperature, and pipeline material...
Calculate suitable NFB and pipeline diameter for installation.

2. Main switch primary side pipeline and secondary side copper inspection selection: according to the capacity of the main switch NFB, provide the primary side distribution pipeline diameter and secondary side
Specification of secondary side copper bar.

Congratulations, you found it!
Mechanical and electrical (hydropower) engineering tools.
Such a tool can satisfy your query and calculate the NFB (number of poles-AT/AF) of various electrical loads and a practical small tool for suitable distribution pipeline diameter.

-4.2MB installed space, is a practical tool, super space saving.

Function application

►This system provides the maximum distance (MAX) that the pipeline of the circuit can be equipped with in the load calculation when the shunt pressure drop is less than 3%, so as to avoid the pressure drop >3% caused by the installation length. And violate the regulations.

►[Main switch primary side pipeline check and selection] The recommended length L of the trunk line is calculated and displayed based on the pressure drop of 2%.

►The ambient temperature of the wire configuration will affect the ampere capacity of the wire; therefore, this system specially incorporates this factor into the calculation; please pay special attention to the ambient temperature of the wire configuration during the review; include it in the review, and have obtained the appropriate Wire distribution.

If you have any questions or suggestions, please contact line.token@gmail.com
V1.001.21 更正導線絕緣溫90度,周溫40度時期修正係數由0.96改為0.95。
V1.001.20 針對2020-02-11 公布 [用戶用電設備裝置規則]更新修訂,相關各類電纜線安培值對應修正。